FLOW

Mass Meter Coriolis for Hydrogen, Ultra High Pressure 35/70 MPa
Accuracy: 0.15%, 0.2%, 0.5%, 1.0%
Density: ± 0.001g / cm3
Temp. Atmosphere: -40 ℃ ~ + 55 ℃
Medium Temp .: -40 ℃ ~ + 70 ℃
Power supply: 12VAC ~ 30VAC / 15VDC ~ 40VDC
Output: Modbus / RS-485, Pulse, 4-20mA / HART
Tube Material: 316L, Hastelloy
Nominal diameter: DN04, DN08, DN15
Flow Range: 8 ~ 17kg / min, 18 ~ 39kg / min, 80 ~ 176kg / min
Protection: IP67

Mass Meter Coriolis for Compressed Natural Gas (CNG) 25 MPa
Accuracy: 0.15%, 0.2%, 0.5%, 1.0%
Density: ± 0.001g / cm3
Temp. Atmosphere: -40 ℃ ~ + 55 ℃
Medium Temp .: -40 ℃ ~ + 70 ℃
Power supply: 12VAC ~ 30VAC / 15VDC ~ 40VDC
Output: Modbus / RS-485, Pulse, 4-20 mA / HART
Tube material: 316L, Hastelloy
Nominal diameter: DN04, DN08, DN15
Flow Range: 8 ~ 17kg / min, 18 ~ 39kg / min, 80 ~ 176kg / min
Protection: IP67

Mass Meter Coriolis for Cryogenic Liquid LNG -196 ° C
Accuracy: 0.15%, 0.2%, 0.5%, 1.0%
Density: ± 0.001g / cm3
Temp. Atmosphere: -40 ℃ ~ + 55 ℃
Medium Temp .: -196 ℃ ~ + 70 ℃
Power supply: 12VAC ~ 30VAC / 15VDC ~ 40VDC
Output: Modbus / RS-485, Pulse, 4- 20 mA / HART
Tube material: 316L, Hastelloy
Nominal diameter: DN04, DN08, DN15
Flow Range: 18 ~ 39kg / min, 220 ~ 485kg / min, 750 ~ 1653kg / min
Protection: IP67

Mass Meter General Purpose Coriolis, option on CNG 25 MPa
Accuracy: 0.15%, 0.2%, 0.5%, 1.0%
Density: ± 0.001g / cm3
Temp. Ambient: -30 ℃ ~ + 60 ℃
Medium Temp .: -200 ℃ ~ + 200 ℃
Power supply: 12VAC ~ 30VAC / 15VDC ~ 40VDC
Output: RS-485, Pulse, 4-20mA / HART
Tube material: 316L, Hastelloy
Connection: Thread 32x1.5, Flanged DN06, DN15, DN20, DN25, DN40
Max Flow: 18kg / min, 50kg / min, 70kg / min 120kg / min, 200kg / min, 500kg / min
* Sealand: Interchangeable transmitters between them.
* Sealand: Native Atex, Ex

Mass Meter Sanitary Coriolis
Accuracy: 0.15%, 0.2%, 0.5%, 1.0%
Density: ± 0.001g / cm3
Temp. Atmosphere: -40 ℃ ~ + 55 ℃
Medium Temp .: -40 ℃ ~ + 70 ℃
Power supply: 12VAC ~ 30VAC / 15VDC ~ 40VDC
Output: Modbus / RS-485, Pulse, 4-20 mA / HART
Tube material: 316L, Hastelloy
Process Connection: Threaded, Flanged, Sanitary quick connection
Nominal diameter: DN15, DN25, DN40, DN50
Flow Range: 108 ~ 238kg / min, 300 ~ 661kg / min, 750 ~ 1653kg / min, 1166 ~ 2570kg / min
Protection: IP67

Vortex Meter
Nominal Pressure (MPa): 1.6, 2.0, 2.5, 4.0
Accuracy: 1.5%
Instrument Material: 304 (316L, Hastelloy is optional)
Speed range (m / s): Gas 3 ~ 60, Steam 3 ~ 70
Output: pulse voltage, 4-20mA, RS485
Ambient Temp .: -20 ℃ ~ + 55 ℃;
Humidity ≤90% RH
Explosion-proof Type: ExiaⅡCT1 ~ T4
Protection: IP65

Mass Meter Coriolis
General Purpose 2 ", 3"
Accuracy: 0.15%, 0.2%, 0.5%, 1.0%
Density: ± 0.001g / cm3
Temp. Ambient: -30 ℃ ~ + 60 ℃
Medium Temp .: -200 ℃ ~ + 200 ℃
Power supply: 12VAC ~ 30VAC / 15VDC ~ 40VDC
Output: RS-485, Pulse, 4-20mA / HART
Tube material: 316L, Hastelloy Connection: Thread 32x1.5, Flanged
Max Flow: 2 ”: 1000kg / min, 3”: 3000kg / min
* Sealand: Interchangeable transmitters between them.
* Sealand: Native Atex, Ex

Integral Electromagnetic Meter
Accuracy: ± 0.5% standard; ± 0.2% optional
Output: 4-20mA
Repeatability: ± 0.1%
Dimension / Linining: PTFE DN10- DN500, Rubber DN65- DN2000
Sensor material: SS321
Housing material: Aluminum
Electrodes Material: SS316L / Hastelloy C / Titanium / Platinum
Measurement Range: <0.1m3 / h -> 1000m3 / h
Power supply: 85-265Vac, 24VDC, 12VDC
IP67 protection

Float flow meter
Measuring range: water 2.5 ~ 180000L / h, air (20 ℃ 101325Pa) 0.07 ~ 1800m3 / h
Accuracy: 2.5%, 1.5%
Working pressure: 1.6MPa ~ 4.0MPa;
Medium Temp .: -80 ~ + 300 ℃
Ambient Temp .: -25 to + 120 ℃
Viscosity: DN 15 ~ 150 ≤ 5mPa.s;
Protection: IP65
Power supply: 24 (1 ± 10%) V DC
Output: 4 - 20 mA DC, 2-wire (optional HART)
Explosion-proof Type: Exia Ⅱ CT1-T4

Industrial Coriolis Mass Meter
Accuracy: 0.15%, 0.2%, 0.5%, 1.0%
Medium Temp .: -40 ℃ ~ + 150 ℃
Power supply: 12VAC ~ 30VAC / 5VDC ~ 40VDC
Output: Modbus / RS-485, Pulse, 4-20mA Current Loop / HART
Medium to Measure: Gas, Liquid and Multi-phase Liquid
Tube Material: 316L, Hastelloy
Nominal Diameters: DN04, DN08, DN15, DN25, DN50, DN80
Flow Range: 8 ~ 17kg / min, 18 ~ 39kg / min, 80 ~ 176kg / min, 18 ~ 39kg / min, 220 ~ 485kg / min, 750 ~ 1653kg / min, 1800 ~ 3968kg / min
Protection: IP67

Remote Electromagnetic Meter
Accuracy: ± 0.5% standard; ± 0.2% optional
Output: 4-20mA
Repeatability: ± 0.1%
Dimension / Linining: PTFE DN10- DN500, Rubber DN65- DN2000
Sensor material: SS321
Housing material: Aluminum
Electrodes Material: SS316L / Hastelloy C / Titanium / Platinum
Measurement Range: <0.1m3 / h -> 1000m3 / h
Power supply: 85-265Vac, 24VDC, 12VDC
IP67 protection
Ultrasonic flow meter
with GPRS Option
Pressure Maximum: 1.6MPa
Temp. Class: T30, T50, T70, T90
Power: 6 -15 year lithium battery
Output: RS485 (adjustable baud rate)
Pulse (default 2ml / pulse, changeable)
To opt! NB-IOT GPRS
Medium to Measure: Water
Tube Material: 316L, Hastelloy
Nominal Diameters, Flanges: DN50-DN300
Flow Range: Variable by application
Display: 9 digit LCD volume, m / s, pressure, error alarm, direction flow, low battery alarm, output.
RS485: 400bps, 4800bps, 9600bps, 19200bps Modbus-RTU)
Protection: IP67